Technology Commodum
Totum chalybeum multi iacuit explosio-probationis structura, cavitatis centrifugae chalybs immaculata.
Tutela libera DC variabili frequentia motoria coegi, operatio lenis et quieta.
Microcomputarius processus subtilis moderatio, ostentatio digitalis, operatio facilis, calculus latae vis centrifugae RCF valor, celeritas et vis centrifugae inter se ab una clave permutari possunt.
Compressorem libero-compressoris unitatis adoptat fluorinum, refrigerationem duplicem-cycli, facultatem caloris et frigoris commutationem validam, temperatura subtilis temperantiam, ieiunium refrigerationem et nullam pollutionem environmental.
Celeritas accelerationis et retardationis moderatio, copia 10 circulorum programmatum communiter adhibitorum.
Mute latae electronicae ianuae seram, facile ad usum, munus aperiens portae subitis.
Ver conus manica ad rotorem et stipitem iungendum adhibetur.Rotor simplex et velox est instituere et removere, non-directional, tuta et certa.
Ostium clausum, velocitas, temperatura et inaequalitas latis tutelae, error sui diagnostica.
Transierunt ISO 9001, ISO 13485, CE, TUV certificatione.
Max Volo | 16000r/min | Max RCF | 20600* g |
Max Volume | 6*100ml | Temperatus dolor | -20℃~40℃ |
Timer | 1~9h/59min | sonitus | ≤60dBA |
Dimension | 610*570* 370mm | Net Pondus | 82KG |
Celeritas Accuracy | ±20r/min | Potentia copia | AC220/100V,50/60HZ,10A |
Temperatus Accuracy | ±1℃ |
TGL16 matched Rotors
Rotors No. | Rotors type | Max celeritas (r / min) | Volumen(ml) | Max RCF (×g) |
No30401 | Angulus rotor | 16000r/min | 12×1.5/2ml | 17940×g |
No30402 | Angulus rotor | 14000r/min | 40×0.5ml | 19970×g |
No30403 | Angulus rotor | 15000r/min | 24×1.5/2ml | 20600g |
No30404 | Angulus rotor | 13500r/min | 30×1.5/2ml | 19340×g |
No30405 | Angulus rotor | 15000r/min | 16×5ml | 19350g |
No30406 | Angulus rotor | 14000r/min | 12×7ml | 16370×g |
No30407 | Angulus rotor | 10000r/min | 12×15ml | 11840×g |
No30408 | Angulus rotor | 12000r/min | 12×10ml | 14510×g |
No30409 | Angulus rotor | 12000r/min | 8×20ml | 14510×g |
No30410 | Angulus rotor | 12000r/min | 6×30ml | 14000×g |
No30411 | Angulus rotor | 11000r/min | 6×50ml | 13480×g |
No30412 | Angulus rotor | 10000r/min | 6×70ml | 10810×g |
No30413 | Angulus rotor | 10000r/min | 4×100ml | 10310×g |
No30414 | Angulus rotor | 10000r/min | 6×100ml | 11380×g |
No30415 | Angulus rotor | 14000r/min | 6×10ml | 16460×g |
No30416 | Angulus rotor | 15000r/min | 30×0.5ml | 18510×g |
No30639 | Angulus rotor | 5000r/min | 24×15ml | 3080×g |
No30627 | Angulus rotor | 5000r/min | 30×15ml | 3830×g |
No30437 | Rotor adductius | 12000r/min | 24 PCs Capillary | 15800×g |
No30444 | Angulus rotor | 11000r/min | 48×1.5/2ml | 12840×g |
No30980 | Rotor adductius | 13000r/min | 4×5ml | 14960×g |
No30935 | Vertical rotor | 14000r/min | 16×5ml | 12660×g |
No30676 | Microplate rotor | 4000r/min | 2×3×48 Bene | 2300×g |
No306 | Angulus rotor | 14000r/min | 4×8PCR(0.2ml) | 12070×g |
No306 | Angulus rotor | 13000r/min | 6×8PCR(0.2ml) | 16080×g |
No306 | Angulus rotor | 14000r/min | 8×8PCR(0.2ml) | 13390×g |
No306 | Angulus rotor | 13000r/min | 12×8PCR(0.2ml) | 17220×g |